中文摘要: 采用高压水热釜处理后,利用电感耦合等离子体原子发射光谱(ICP-AES)法测定碳纳米管中负载的铂。对仪器参数以及被测元素的谱线选择进行了讨论。在选定最佳条件下,探讨了检测方法中检出限、精密度及加标回收率等指标,方法相对标准偏差小于5%(n=5),加标回收率为 101%~114%。方法实用性强,可成功应用于碳纳米管中负载的Pt的快速检测。
中文关键词: ICP-AES  铂纳米粒子  碳纳米管
Abstract:The loading amount of Pt on carbon nanotubes (CNTs) was determined by inductively-coupled plasma atomic emission spectrometry (ICP-AES) after the acid-treatment process in an autoclave. The instrument parameters and the analytical lines of Pt were discussed. The Pt concentration was determined at the optimum conditions. The relative standard deviation (RSD) was less than 5% (n=5) and the recoveries were in the range of 101 % ~ 113 %. This method is practical and can be successfully applied to the detection of Pt on carbon nanotubes.
keywords: ICP-AES  Pt Nanoparticles  CNTs
文章编号:     中图分类号:    文献标志码:
基金项目:
引用文本:
那 铎,孙 莹,马洪波.电感耦合等离子体原子发射光谱(ICP-AES)法测定碳纳米管负载铂催化剂中铂的含量[J].中国无机分析化学,2017,7(4):93-96.
NA Duo,SUN Ying,MA Hongbo.Determination of the Pt Loading Amount on Carbon Nanotubes by Inductively-Coupled Plasma Atomic Emission Spectrometry (ICP-AES)[J].Chinese Journal of Inorganic Analytical Chemistry,2017,7(4):93-96.

我们一直在努力打
造,精品期刊,传
播学术成果

全国咨询服务热线
86-10-63299759

杂志信息

期刊简介

相关下载

联系我们

电话:010-63299759

传真:010-63299754

QQ:XXXXXXX

Email:zgwjfxhx@163.com

邮编:100160

地址:北京市南四环西路188号总部基地十八区23号楼

关注微信公众号