WU Dongmei,ZHAO Yanqiu,FU Guoyu,YU Shushi,YU Zhongqi,TAN Ting and LIU Qianyang
(Beijing Beifen-Ruli Analytical Instrument (Group) Co., Ltd,Beijing Beifen-Ruili Analytical lnstrument (Group) Co.,Ltd,Beijing Beifen-Ruli Analytical Instrument (Group) Co., Ltd,Beijing Beifen-Ruli Analytical Instrument (Group) Co., Ltd,Beijing Beifen-Ruli Analytical Instrument (Group) Co., Ltd,Beijing Beifen-Ruli Analytical Instrument (Group) Co., Ltd,Beijing Beifen-Ruli Analytical Instrument (Group) Co., Ltd)
摘要
图/表
参考文献
相似文献
本文已被:浏览 1285次   下载 706
投稿时间:2018-01-26    修订日期:2018-01-30
中文摘要: 在分析仪器测量中,当元素含量变化较大时,部分低含量和高含量的样品很难得到理想的测试结果。通过使用多条工作曲线来扩大元素测量的动态范围,在北京北分瑞利分析仪器有限公司新研发的AES-8000全谱交直流电弧发射光谱仪上,使用该方法对地质样品中的不同含量的铅进行检测,结果表明,用多工作曲线法,测得的铅含量与推荐值更接近,即准确度更好。待测样品含量首先由第一条灵敏度高的曲线进行测量,若测定浓度大于该曲线的转换值,则由第二条灵敏度较低的工作曲线进行测量,以此来拓宽检测的上下限。转换值的设定要充分考虑工作曲线的衔接问题,设定的转换值浓度应该在衔接的两条工作曲线上都处于线性部分。使用多工作曲线法,设定合理的转换值,可以同时获得高、低含量样品的理想测试结果。
Abstract:Instrument analysis, when the element content changes greatly, part of the low content and high content of sample is hard to get ideal results. Through the use of multiple calibration curve to enlarge the dynamic range of element measurement. On the AES-8000 full spectrum ac/dc arc emission spectrometer, using this method to test the different content of plumbum elements in the geological samples, and the results show that the measured Plumbum content is closer to the recommended value, i.e. the accuracy is better. In order to broaden the dynamic range, the sample is measured by the first curve of high sensitivity, if the concentration is greater than the conversion value, measured by the second curve of low sensitivity. Cohesion between two curves should be fully considered, the conversion value should be in the linear part of the two curves. Using multiple calibration curve method, setting reasonable conversion value, the high and low content of samples of ideal test results can be obtained at the same time.
文章编号:     中图分类号:    文献标志码:
基金项目:
引用文本:
吴冬梅,赵燕秋,付国余,余澍时,于中奇,谭婷,刘欠洋.多工作曲线-全谱交直流电弧发射光谱法测定地质样品中的铅含量[J].中国无机分析化学,2018,8(3):16-18.
WU Dongmei,ZHAO Yanqiu,FU Guoyu,YU Shushi,YU Zhongqi,TAN Ting,LIU Qianyang.A Multi - Calibration Curve - Full Spectrum ac/dc Arc Emission Spectrometry was Used to Determine the Plumbum Content in Geological Samples.[J].Chinese Journal of Inorganic Analytical Chemistry,2018,8(3):16-18.