中国无机分析化学:2019,9(3):37-39
←前一篇   |   后一篇→
本文二维码信息
码上扫一扫!
电感耦合等离子体原子发射光谱(ICP-AES)法测定锌-铝-镉牺牲阳极中多种元素含量
(1.江阴市产品质量监督检验所 江苏江阴 214434;2.国家船舶材料质量监督检验中心江苏 江苏江阴 214434)
Determination of Multiple Elements in Zinc-aluminum-cadmium Sacrificial Anode by ICP-AES
摘要
图/表
参考文献
相似文献
本文已被:浏览 253次   下载 76
投稿时间:2018-12-27    修订日期:2018-12-27
中文摘要: 利用稀王水溶解试样,建立了电感耦合等离子体原子发射光谱测定锌-铝-镉牺牲阳极中铝、镉、铁、铅、铜和硅6种元素的分析方法。各元素的精密度均小于5%,检出限及回收率分别在0.0012%~0.016%和94.6%~105.0%。用本方法对实际样品进行分析,检测结果与其他实验室结果一致。
Abstract:ICP-AES was applied to determination of Al, Cd, Fe, Pb, Cu and Si in zinc-aluminum-cadmium sacrificial anode by dissolving specimen with dilute chlorazotic acid. The precision of each element was less than 5%. The detection limit and recovery materials were 0.0012%-0.016% and 94.6%-105.1% respectively. The actual samples were analyzed by this method, which were consistent with the results from other laboratory.
文章编号:     中图分类号:    文献标志码:
基金项目:
引用文本:
冯秀梅,常守勤,陈连芳,陈君.电感耦合等离子体原子发射光谱(ICP-AES)法测定锌-铝-镉牺牲阳极中多种元素含量[J].中国无机分析化学,2019,9(3):37-39.