中文摘要: 采用微波消解技术处理冰铜样品,选择As 188.979 nm、Hg 194.227 nm为分析谱线,建立了电感耦合等离子体原子发射光谱法(ICP-AES)测定冰铜中砷和汞。实验表明:此方法可将试样溶解完全。砷检出限 3.1 ug/g、汞检出限0.7 ug/g,该方法操作简便、快速,该方法的测定值与传统方法的测定值相符。加标回收率在95%~110%、相对标准偏差小于4%,可满足冰铜中砷和汞的准确测定。
Abstract:The sample of copper matte was treated by microwave digestion method. As 188.979 nm and Hg 194.227 nm were selected as the analytical lines. A determination method of arsenic and mercury content in copper matte was established by inductively coupled plasma atomic emission spectriometry(ICP-AES). The results showed that the sample of copper matte could be completely dissolved by this method. The detection limit for arsenic is 3.1 ug/g and for mercury is 0.7 ug/g. The method is simple and fast. The elements recoveries ranged from 95 % to 110 %,and the relative standard deviation was less than 4 %, this method could reach the determination requirements of arsenic and mercury content in copper matte.
文章编号:     中图分类号:    文献标志码:
基金项目:
引用文本:
吕茜茜.微波消解-电感耦合等离子体原子发射光谱(ICP-AES)法同时测定冰铜中砷和汞[J].中国无机分析化学,2019,9(4):24-26.
lvqianqian.Determination of Arsenic and Mercury Content in Copper Matte by Microwave Digestion-ICP-AES[J].Chinese Journal of Inorganic Analytical Chemistry,2019,9(4):24-26.

我们一直在努力打
造,精品期刊,传
播学术成果

全国咨询服务热线
86-10-63299759

杂志信息

期刊简介

相关下载

联系我们

电话:010-63299759

传真:010-63299754

QQ:XXXXXXX

Email:zgwjfxhx@163.com

邮编:100160

地址:北京市南四环西路188号总部基地十八区23号楼

关注微信公众号