中国无机分析化学:2020,10(2):11-14
←前一篇   |   后一篇→
本文二维码信息
码上扫一扫!
火焰原子吸收光谱法测定镍基高温合金中的镉
吕婷,郭颖
(上海材料研究所)
Determination of Cadmium in Nickel Base Superalloy by Flame Atomic Absorption Spectrometry
LYU Ting,GUO Ying
(Shanghai Research Institution of Materials)
摘要
图/表
参考文献
相似文献
本文已被:浏览 120次   下载 99
投稿时间:2019-07-29    修订日期:2019-07-29
中文摘要: 试验采用火焰原子吸收光谱法测定镍基高温合金中的镉,样品以硝酸-氢氟酸-水混合溶液(1+1+1)前处理,选择 Cd 228.8 nm 为分析线进行测定,并通过标准加入法校正基体效应。试验考察了消解酸的选择,仪器工作参数的调整,基体和共存离子对镉测定的影响。结果表明,镍基高温合金中镉的检出限为 0.088 μg/g。加标回收率为 94.1~109.3 % ,结果的相对标准偏差(RSD,n=8)在 0.54~1.6 % 之间。该方法操作简便,分析速度快,准确度好,适用于镉含量在 0.0001~0.001% 之间的镍基高温合金中镉的测定。
Abstract:The flame atomic absorption spectrometry (FAAS) method was established for determination of cadmium in nickel base superalloy. Samples of nickel base superalloy were digested with a mixture of nitric acid, hydrofluoric acid and water(1+1+1), and Cd 228.8 nm was selected as analytical lines. The standard addition method was used to prepare calibration curve to eliminate the matrix effect.The selection of digestive acid, the optimization of instrument parameters, the influences of matrix and coexisted ions on the determination of were also studied. The results showed that: The detection limit was 0.088 mg/L for Cd, the recovery rates in the samples were ranged from 94.1% to 109.3 %, and the relative standard deviations (RSD, n = 8) of determination results were between 0.54 % and 1.6 %. The method is simple, rapid and accurate, and thus suitable for the analysis of the cadmium in nickel base superalloy with cadmium content of 0.0001 ~ 0.001 %.
文章编号:     中图分类号:    文献标志码:
基金项目:
引用文本:
吕婷,郭颖.火焰原子吸收光谱法测定镍基高温合金中的镉[J].中国无机分析化学,2020,10(2):11-14.
LYU Ting,GUO Ying.Determination of Cadmium in Nickel Base Superalloy by Flame Atomic Absorption Spectrometry[J].Chinese Journal of Inorganic Analytical Chemistry,2020,10(2):11-14.

我们一直在努力打
造,精品期刊,传
播学术成果

全国咨询服务热线
86-10-63299759

杂志信息

期刊简介

相关下载

联系我们

电话:010-63299759

传真:010-63299754

QQ:XXXXXXX

Email:zgwjfxhx@163.com

邮编:100160

地址:北京市南四环西路188号总部基地十八区23号楼

关注微信公众号