本文已被:浏览 221次 下载 111次
投稿时间:2024-01-24 修订日期:2024-01-29
投稿时间:2024-01-24 修订日期:2024-01-29
中文摘要: 为准确测定沉积物中痕量铅和砷的含量,采用电感耦合等离子体质谱 (ICP-MS) 测定,比较不同消解方式与不同混合酸体系对沉积物中铅和砷元素的提取效果,并讨论内标法和标准加入法对质控结果的影响,建立了电热板消解 / ICP-MS标准加入法同时测定水系沉积物中铅和砷元素含量的方法。通过分析经认证的标准参考样 (GSD-9)来评价方法的准确度。结果显示,采用HCl-HNO3-HF-HClO4体系电热板消解,具有较高的消化回收率;标准加入法可有效清除基质干扰,提高准确度。方法线性关系良好,铅和砷元素的回收率在93.9%~104%之间,相对标准偏差为4.2%~5.0% (n=6),检出限分别为0.026 mg/kg和0.0036 mg/kg。表明该方法的准确度和精密度良好、灵敏度高。利用建立的方法测定了3个水系沉积物中的铅和砷含量,为环境中土壤及水系沉积物中痕量重金属元素含量的测定提供了可靠的分析方法。
Abstract:In order to improve the accuracy of trace lead (Pb) and arsenic (As) in sediment, inductively coupled plasma mass spectrometry (ICP-MS) was used to compare the extraction effects of different digestion methods and different mixed acid systems on lead (Pb) and arsenic (As) in sediment, and to discuss the influence of internal standard method and standard addition method on quality control. A method was developed for the analysis of Pb and As in sediment using ICP-MS with electric heating plate digestion and standard addition method. The accuracy of the method was evaluated by analyzing the certified reference material (GSD-9). The results showed that the digestion recoveries of the samples digested by HCl-HNO3-HF-HClO4 and electric heating plate digestion were higher than other digestion methods, and the standard addition method could effectively eliminate the matrix interference with improved accuracy. The linear relationship of the method was good, and the recoveries of Pb and As were in the range of 93.9%~104% with the relative standard deviations (RSD, n=6) from 4.2% to 5.0%, and the detection limits of Pb and As were 0.026 mg/kg and 0.0036 mg/kg, respectively. It shows that the method has good accuracy, adequate precision and high sensitivity. The contents of Pb and As in sediments of three river systems were successfully determined by the proposed method, which provided a reliable analysis method for the determination of trace heavy metal elements in soil and sediment in the environment.
keywords: sediment electric heating plate digestion inductively coupled plasma-mass spectrometry standard addition method lead arsenic
文章编号: 中图分类号:O657.63; TH843 文献标志码:
基金项目:无
引用文本:
吴怡,虞锐鹏,陈海兰,曹玉华,李明.电感耦合等离子体质谱(ICP-MS)法同时测定水系沉积物中痕量铅和砷[J].中国无机分析化学,2024,14(11):1471-1477.
WU Yi,YU Rui-peng,CHEN Hai-lan,CAO Yu-hua,LI Ming.Simultaneous Determination of Trace Lead and Arsenic in Sediment by ICP-MS inductively coupled plasma-mass spectrometry[J].Chinese Journal of Inorganic Analytical Chemistry,2024,14(11):1471-1477.
吴怡,虞锐鹏,陈海兰,曹玉华,李明.电感耦合等离子体质谱(ICP-MS)法同时测定水系沉积物中痕量铅和砷[J].中国无机分析化学,2024,14(11):1471-1477.
WU Yi,YU Rui-peng,CHEN Hai-lan,CAO Yu-hua,LI Ming.Simultaneous Determination of Trace Lead and Arsenic in Sediment by ICP-MS inductively coupled plasma-mass spectrometry[J].Chinese Journal of Inorganic Analytical Chemistry,2024,14(11):1471-1477.