Improving the Analytical Method for Determination of Calcium Oxide in Blast Furnace Slag
Received:May 26, 2011  Revised:June 28, 2011
View Full Text  View/Add Comment  Download reader
DOI:10.3969/j.issn.2095-1035.2011.03.0013
KeyWord:blast furnace slag; calcium oxide; EDTA titrimetric method
  
AuthorInstitution
FU Yongji 湖南东港锑品有限公司, 湖南 永州
Hits: 3406
Download times: 2047
Abstract:
      Based on the methodology of DHF83B high speed multi-element analysis instrument, we improved the analytical method for determination of calcium oxide in blast furnace slag. We used (1+1) hydrochloric acid to dissolve sample, and use triethanolamine as the masking agents for the residual elements including iron, aluminum, manganese and so on. At pH bigger than 12, EDTA standard solution was used to titrate calcium oxide using calcium indicator as the titration indicator and the content of calcium oxide was determined. Relative standard deviation (RSD) of the EDTA titrimetric method is 2.82%, and the analytical results are basically consistent with those obtained according to the DHF83B methodology. It concluded that our method is accurate, fast and simple and is suitable for application in determination of calcium oxide in melt furnace slag.
Close