Determination of Copper in Copper Matte by Iodometric Titration Method
Received:January 15, 2013  Revised:February 01, 2013
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.2095-1035.2013.03.006
KeyWord:copper matte;copper content;measurment
              
AuthorInstitution
SONG Fei 山东出入境检验检疫局 山东 青岛
DING Shibing 山东出入境检验检疫局 山东 青岛
MIN Guohua 山东出入境检验检疫局 山东 青岛
LIU Zhi 山东出入境检验检疫局 山东 青岛
ZHANG Qingjian 山东出入境检验检疫局 山东 青岛
Hits: 1729
Download times: 291
Abstract:
      An iodometric titration approach was established for determination of copper in copper matte based on the composition and structure characteristics of copper matte. The focus of this paper is to investigate the sample pretreatment of dissolving copper matte sample with mixed acid and the titration procedures. Using the developed approach, the concentration range of copper that can be determined was from 4.80% to 32.00% with the relative standard deviations of 0.24 % -0.53%. The copper recoveries were from 97.70% to 101.26%. This study solved the problems in the determination of copper content in copper matte.
Close