Microwave digestion and determination of manganese,phosphorus,nickel,copper,chromium and vanadium in high-speed tool steel by ICP-AES
Received:January 22, 2014  Revised:February 12, 2014
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:Microwave digestion; ICP-AES; high-speed tool steel; matrix matching
        
AuthorInstitution
HE Xiao-hu 广西冶金产品质量监督检验站
GAN Ri-xing 广西冶金产品质量监督检验站
WEI Li 广西冶金产品质量监督检验站
Hits: 1067
Download times: 209
Abstract:
      High speed tool steel is a kind of high alloy tool steel with high carbon, it is difficult to be dissolved at room temperature. In this paper, by using microwave digestion improves digestion temperature and pressure, samples were full digested in hydrofluoric acid, sulfuric acid and aqua regia medium, by adding saturated boric acid solution complexation excess of hydrogen fluoride acid, and matrix matching to eliminate the influence of the iron matrix by ICP-AES method for simultaneous determination of manganese, phosphorus, copper, nickel,,chromium, vanadium content.. Determination of high speed tool steel standard, the measured value is consistent with the certified values. The precision of this method is in 0.55% ~ 4.06%,the recoveries were 95.6% ~ 114.8%. This method can meet the requirements of the measurement.