Determination of silver, lead, cadmium in high antimony smoke by flame atomic absorption spectrometry
Received:May 05, 2014  Revised:May 24, 2014
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:flame;atomic absorption;spectrometry, high;antimony fumes, silver, lead, cadmium
     
AuthorInstitution
Huang Jianhui 中国有色桂林矿产地质研究院有限公司
Lu Handi 中国有色桂林矿产地质研究院有限公司
Hits: 1484
Download times: 318
Abstract:
      The analysis method is used to determine silver, lead, cadmium in high antimony smoke by flame atomic absorption spectrometry. After aqua regia, perchloric acid dissolution, with the use of tetravalent antimony bromide of lower boiling point nature, antimony will be removed from samples to eliminate the matrix interference of antimony. In hydrochloric acid - perchloric acid - thiourea medium silver, lead, cadmium are analyzed simultaneously. The detection limit: Ag is 0.0037μg/mL, Pb is 0.0198μg/mL, Cd is 0.0016μg/mL. Precision (RSD, N = 11): Ag was 0.92% ~ 1.04%, Pb was 1.29% ~ 2.21%, Cd of 1.99% ~ 2.22%. Recoveries: Ag was 99.30% ~ 101.8%, Pb was 98.60% ~ 102.5%, Cd was 98.40% to 104.0%. The method is accurate, reliable, simple, fast and totally for the silver, lead, cadmium determination of high antimony smoke.
Close