Determination of major and minor components of rutile by X-ray fluorescence spectrometry |
Received:January 11, 2015 Revised:April 20, 2015 |
View Full Text View/Add Comment Download reader |
DOI: |
KeyWord:X-ray fluorescence spectrometry;rutile;fusion sample preparation |
Author | Institution |
YANG ming-kun |
厦门出入境检验检疫局技术中心 |
|
Hits: 975 |
Download times: 203 |
Abstract: |
A method has been developed for determination of contents of TiO2、TFe、P、SiO2、Al2O3、MnO、CaO、Cr2O3、MgO、ZrO2、HFO2 in rutile ores by wavelength dispersion X-ray fluorescence spectrometrv. The samples were fused into test portion with the mixture flux of Li2B4O7-LiBO2(67 33) at 1150℃ for 90 s. The sample-flux ratio was set at the proportion of 14:1. The fused glass slices were proved to be homogeneous, strengthful and with a good shape. The method was applied to the determination of real rutile ore samples, and the measured values were in a good agreement with the reference values or the values determined by chemical methods. The relative standard deviation (RSD, n=10) of all other analytes were less than 2%, except of P 3.8% and Al2O3 2.8%. |
Close |