Determination of Ca, Mg and Zn in Water-glycol Fire-resistant Hydraulic Fluid by ICP-AES |
Received:August 31, 2015 Revised:December 10, 2015 |
View Full Text View/Add Comment Download reader |
DOI:doi:10.3969/j.issn.2095-1035.2016.01.010 |
KeyWord:ICP-AES; water-glycol fire-resistant hydraulic fluid; matrix matching; direct sampling |
Author | Institution |
ZHENG Qingbo |
海军工程大学 青岛油液检测分析中心,山东 青岛 |
LIU Dongfeng |
海军工程大学 青岛油液检测分析中心,山东 青岛 |
SHI Xinfa |
海军工程大学 青岛油液检测分析中心,山东 青岛 |
|
Hits: 1518 |
Download times: 0 |
Abstract: |
A new method for the determination of Ca, Mg and Zn in water-glycol fire resistant hydraulic fluid was established by ICP-AES. The spectral interferences were eliminated by matrix matching method and the sampling volume was reduced, which leading to direct sampling owing to decreasing the atomization gas flow, improving the cooler flow and reducing the peristaltic pump speed. The results showed that the relative standard deviation (RSD) of each determined element was less than 5%, the linear correlation coefficient was over 0.999, and the detection limits were less than 0.15 mg/L with 97%~105% recovery. The method has quick analytical speed, easy operation and reliable analytical results without sample pre-treatment. It is suitable for the determination of the contents of Ca, Mg and Zn in water-glycol fire resistant hydraulic fluid. |