Determination of Thallium in Lead-Zinc Concentrate by Inductively Coupled Plasma Atomic Emission Spectrometry
Received:August 21, 2016  Revised:October 09, 2016
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.2095-1035.2017.02.003
KeyWord:lead-zinc concentrate; thallium; ICP-AES
     
AuthorInstitution
LI Yanqun 株洲冶炼集团股份有限公司,湖南 株洲
XIANG Delei 株洲冶炼集团股份有限公司,湖南 株洲
Hits: 1064
Download times: 0
Abstract:
      The contents of Tl in Lead-Zinc concentrate samples were determined by ICP-AES after the samples were dissolved in nitric acid, hydrochloric acid, hydrofluoric acid and perchloric acid and the solution was diluted. The measurement range was from 0.005% to 0.05%. By experiments, the appropriate solution acidity and the correction method for interference elements were determined. The relative standard deviations(n=7) were between 1.3% and 4.8%, and the recoveries were in the range from 93.7% to 102%. ?Due to less interference, fast speed and accuracy, the method is applicable for the determination of Tl concentration for the batch samples of Lead-Zinc concentrate.