Determination of Gold and Silver in Copper Anode by Fire Assay-Gravimetric Method |
Received:February 13, 2017 Revised:April 16, 2017 |
View Full Text View/Add Comment Download reader |
DOI:doi:10.3969/j.issn.2095-1035.2017.03.018 |
KeyWord:fire assay; anode copper; gold; silver |
Author | Institution |
LIU Qiubo |
北京矿冶研究总院,北京 |
KANG Yu |
北京矿冶研究总院,北京 |
|
Hits: 1067 |
Download times: 0 |
Abstract: |
Gold and silver content in a copper anode sample were simultaneously determined by a fast fire assay-gravimetric method. The sample was melted at high temperature with the appropriate amount of flux, and lead enriched gold and silver to form a lead buckle. The gold-silver beads were obtained by cupellation of the lead buckle. Gold was separated from the silver-gold alloy bead by treatment with nitric acid. Gold and other impurity elements in the dissolved solution were determined by ICP-AES. The mass of silver was equal to the mass of bead minus the mass of gold and impurity elements. This method showed good precision and high accuracy. The recovery rate of the gold and silver was between 97.6% and 102%. |
Close |