Determination of Lanthanum , Cerium in Copper–steel clad plates for bearings by Inductively coupled plasma atomic emission spectroscopy
Received:July 05, 2018  Revised:July 12, 2018
View Full Text  View/Add Comment  Download reader
DOI:10.3969/j.issn.2095-1035.2018.06.013
KeyWord:inductively coupled plasma atomic emission spectroscopy; Copper–steel clad plates for bearings; La and Ce;
           
AuthorInstitution
NIE Xiaoming 广西冶金产品质量检验站
HE Xiaohu 广西冶金产品质量检验站
HU Yongmei 广西冶金产品质量检验站
WEI Li 广西冶金产品质量检验站
Hits: 1076
Download times: 767
Abstract:
      Copper–steel clad plates for bearings was digested in nitric acid and hydrochloric acid, with Rh as internal standard, using inductively coupled plasma atomic emission spectroscopy (ICP-AES) for determining the intensity of characteristic line of elements to be measured in specimen solution.The contents of La and Ce in specimen were calculated by standard curve method.The precisions of 1 # and 2# copper–steel clad plates for bearings ( RSD ) were in the rate of 0.98% ~ 1.08%,and the recoveries rate were between 97.0% and 104.6%.So the method is accurate and reliable.