Determination of Nickel in Electroplating Waste by Alkali Fusion-ICP-AES
Received:May 29, 2019  Revised:May 29, 2019
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.2095-1035.2020.01.014
KeyWord:electroplating waste; Inductively coupled plasma emission spectrometry: Nickel
  
AuthorInstitution
HAN Xiao 北矿检测技术有限公司
Hits: 1638
Download times: 834
Abstract:
      The nickel content in electroplating waste was determined by Sodium peroxide decomposition sample, hydrochloric acid leaching and inductively coupled plasma atomic emission spectrometry. Determination range: ω (Ni): 0.50% ~ 10.00%. In this paper, an inductively coupled plasma atomic emission spectrometry (ICP-AES) [1] method for determination of nickel content in electroplating waste has been established by using Sodium peroxide alkali fusion, through sample melting time and temperature, instrument conditions, interference experiments of coexisting elements, etc. The method can completely meet the inspection work of nickel content in such materials. The recovery rate of nickel is 92%~105%(n=3) through the standard addition recovery experiment. The method is accurate and simple, and is suitable for nickel determination of electroplating waste.
Close