Determination of Germanium Content in Germanium Concentrate by Inductively Coupled Plasma Optical Emission Spectrometry
Received:February 26, 2020  Revised:March 03, 2020
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.2095-1035.2020.04.011
KeyWord:Inductively coupled plasma optical emission spectrometry; Germanium concentrate; Germanium
  
AuthorInstitution
SU Chunfeng 北矿检测技术有限公司
Hits: 952
Download times: 914
Abstract:
      A method for the determination of germanium in germanium concentrate by inductively coupled plasma emission spectrometry (ICP-OES) was established. The sample was digested in nitric acid , hydrofluoric acid, and phosphoric acid. The detection limit of germanium was 0.006 g/mL, the lower limit was 0.020 g/mL, and the range was 1%-15%, which was consistent with the classical potassium iodate titration method. The relative standard deviation (SRD) less than 3% (n=11), the standard recovery rate is 98%~101%, which can meet the requirements of rapid determination and batch processing of germanium content in germanium concentrate.