Determination of magnesium oxide in silver concentrate by Inductively Coupled Plasma-Optical Emission Spectrometry
Received:October 10, 2020  Revised:January 08, 2021
View Full Text  View/Add Comment  Download reader
DOI:10.3969/j.issn.2095-1035.2021.04.010
KeyWord:silver concentrate; magnesium oxide; Inductively Coupled Plasma-Optical Emission Spectrometry
           
AuthorInstitution
Zhao xin 湖南省地质测试研究院 湖南 长沙
xiaoliujing 湖南省地质测试研究院 湖南 长沙
Jin Dong-yan 湖南省地质测试研究院 湖南 长沙
Tang Xing 湖南省地质测试研究院
Hits: 107
Download times: 84
Abstract:
      A method was established for the determination of magnesium oxide content in silver concentrate by inductively coupled Plasma-Optical Emission Spectrometry after the samples were directly digested by adding mixed acids (5mL hydrofluoric acid, 5mL nitric acid, 5mL hydrochloric acid and 1mL perchloric acid), and extracted by 10 mL(1:1) HCL.The detection limit and determination limit of the method were 0.0016% and 0.0064% respectively,and it was verified by national standard substance GBW07164, and the relative error was 0.43%.In the actual sample analysis, the relative standard deviation (RSD, n=6) of the method was less than 4% compared with the standard method of flame atomic absorption spectrometry, and the analysis results were consistent. The method is simple, rapid and accurate with satisfactory results.