Analysis on lead release from rubber tubes in tap water
Received:March 31, 2021  Revised:May 08, 2021
View Full Text  View/Add Comment  Download reader
DOI:10.3969/j.issn.2095-1035.2021.05.013
KeyWord:Rubber tubes; Tap water; Pb; Content; Release
        
AuthorInstitution
Lu Chunqiang 上海市质量监督检验技术研究院
Dai Yanan 上海市质量监督检验技术研究院
wen shiqiang 上海市质量监督检验技术研究院
Hits: 1234
Download times: 1136
Abstract:
      To investigate the lead release from rubber tubes. Methods The lead content in 3 types of rubber tubes were determined, and the Pb release were analyzed from the rubber tubes under different immersion time and temperature conditions(22,40,60,80,100℃) in tap water. Results The lead content of rubber tubes 3#, 1#, and 2# decreased successively, and the amount of Pb release also decreased successively under the same conditions; The amount of Pb release showed a downward trend with the number of the immersion time increases. As the temperature increased, the amount of Pb release is increasing, and the release rate is also increasing. Conclusion The Pb release of rubber tubes with high lead content is also higher. Pb release decrease gradually as the increasing of the number of immersion time, and it increases with the increase of immersion temperature.