Determination of Ni,Co and Mn content in ternary hydroxides
Received:February 17, 2017  Revised:April 10, 2017
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.2095-1035.2017.03.011
KeyWord:the ternary precursor; ICP-AES;EDTA titration; nickel; cobalt; manganese
  
AuthorInstitution
JIANG Guofen 浙江华友钴业股份有限公司,浙江 桐乡,
Hits: 1601
Download times: 0
Abstract:
      Nickel (Ni), cobalt (Co) and manganese (Mn) content in ternary precursor Ni0.33 o0.33Mn0.33(OH) 2 was determined by instrumental and chemical analyses. The?molar proportion of Ni, Co and Mn was determined by ICP-AES and the total content of the three elements was determined by EDTA titration. Then Ni, Co and Mn content was calculated. Higher precision was obtained by optimizing the experimental conditions. A recovery between 99.2% and 101% was achieved, and the relative standard deviation was lower than 0.65%. The established method is accurate, fast and has been applied to practical analysis.
Close