Determination of Heavy Metal Lead in Neodymium-Iron-Boron with ICP-OES |
Received:November 14, 2018 Revised:March 07, 2019 |
View Full Text View/Add Comment Download reader |
DOI:doi:10.3969/j.issn.2095-1035.2019.02.003 |
KeyWord:ICP-OES;neodymium-iron-boron; heavy metal;lead |
Author | Institution |
zhuxiaolong |
宁波市计量测试研究院 |
|
Hits: 1086 |
Download times: 689 |
Abstract: |
The sample of neodymium-iron-boron magnet was digested by nitric acid. An analysis method was established for determination of heavy metal lead in neodymium-iron-boron magnet with inductively coupled plasma optical emission spectrometer(ICP-OES). The working conditions of the instrument and analysis wavelength were discussed. Results showed that the linear correlation coefficient was 0.99993, the detection limit was 0.009 μg/mL, the recovery of standard addition was 104 %, the accuracy and precision were all less than 3 %. The detection limit of the method was low and met the actual analysis requirements. This method could quickly, conveniently and accurately detect the heavy metal lead in neodymium-iron-boron magnet. |
Close |